Effect of Equivalence Ratio and G-Loading on In-Situ Measurements of Chemiluminescence in an Ultra Compact Combustor - Jason M Armstrong - Libros - Biblioscholar - 9781288292615 - 13 de noviembre de 2012
En caso de que portada y título no coincidan, el título será el correcto

Effect of Equivalence Ratio and G-Loading on In-Situ Measurements of Chemiluminescence in an Ultra Compact Combustor

Precio
$ 25,49
sin IVA

Pedido desde almacén remoto

Entrega prevista 22 de jun. - 9 de jul.
Añadir a tu lista de deseos de iMusic

Publisher Marketing: Using a spectrometer and high temperature fiber optics the relative intensities of the near-infrared, visible and ultraviolet radiation emitted from the C2*, CH*, and OH* radicals were measured at eight discrete locations within the Ultra Compact Combustor test rig. Blackbody radiation in the near infrared was also observed. The tests were conducted at various g-loadings and overall equivalence ratios and with various air hole configurations. These measurements were compared to determine the effect of these changes on the radiatio n emitted. Local C2* intensities were used to estimate the flame location within the combustor and the local CH*/OH* ratio was used as a gauge of the local equivalence ratio within the cavity. Results indicate the highest ratios of CH*/OH* occur in the outer radius of the cavity where the high g-loads transport the colder unreacted fuel and air. The highest C2* ratios also occur in the outer radius. A correlation between cavity equivalence ratio and C2*/OH* was determined for these experiments as well. Fuel droplet size characterization was also conducted using a laser diffraction particle size analyzer. The same pressure atomizer used in the Ultra Compact Combustor test rig was used. Fuel flow conditions simulated the same fuel flow conditions as the test rig. Experiments indicated poor atomization at the lower overall fuel to air ratio test conditions since the fuel flow pressure is relatively low at these test conditions. Combustion efficiencies were also some of the lowest efficiencies measured for these test conditions, which is indicative of poor fuel atomization. All experiments were completed in the Air Force Research Laboratory's Atmospheric Combustion Research Facility at Wright-Patterson AFB. This research supports compact common iv core initiatives of the Versatile, Affordable, Advanced Turbine Engine (VAATE) program.

Medios de comunicación Libros     Paperback Book   (Libro con tapa blanda y lomo encolado)
Publicado 13 de noviembre de 2012
ISBN13 9781288292615
Editores Biblioscholar
Páginas 120
Dimensiones 189 × 246 × 6 mm   ·   176 g

Mere med samme udgiver